should pass through (D) or (G) after a few
seconds. When assured that the fittings are tight, close (h) and open
(a) cautiously to admit air to restore atmospheric pressure. This
precaution is essential, as a sudden inrush of air will project liquid
from (D) or (F'). Reconnect the rubber tube with the flask (A).
Open the pinchcocks (a) and (k) and blow over about 10 cc. of the
hydrochloric acid from (A) into (B). When the action of the acid
slackens, blow over (slowly) another 10 cc.
The rate of gas evolution should not exceed for more than a few
seconds that at which about two bubbles per second pass through (G)
(Note 2). Repeat the addition of acid in small portions until the
action upon the limestone seems to be at an end, taking care to close
(a) after each addition of acid (Note 3). Disconnect (A) and connect
the rubber tubing with the soda-lime tube (K) and open (a). Then close
(k) and open (h), regulating the flow of water from (H) in such a way
that about two bubbles per second pass through (G). Place a small
flame under (B) and !slowly! raise the contents to boiling and boil
for three minutes. Then remove the burner from under (B) and continue
to draw air through the apparatus for 20-30 minutes, or until (H)
is emptied (Note 4). Remove the absorption apparatus, closing the
stopcocks on (F) or stoppering the open ends of (F'), leave the
apparatus in the balance case for at least thirty minutes, wipe it
carefully and weigh, after opening the stopcocks (or removing plugs).
The increase in weight is due to absorption of CO_{2}, from which its
percentage in the sample may be calculated.
After cleaning (B) and refilling (H), the apparatus is ready for the
duplicate analysis.
[Note 1: The absorption tubes or bulbs have large surfaces on which
moisture may collect. By allowing them to remain in the balance case
for some time before weighing, the amount of moisture absorbed on the
surface is as nearly constant as practicable during two weighings, and
a uniform temperature is also assured. The stopcocks of the U-tube
should be opened, or the plugs used to close the openings of the
Geissler bulb should be removed before weighing in order that the air
contents shall always be at atmospheric pressure.]
[Note 2: If the gas passes too rapidly into the absorption apparatus,
some carbon dioxide may be carried through, not being completely
retained by the absorbents.]
[Note 3: The essential ionic changes involved in t
|