FREE BOOKS

Author's List




PREV.   NEXT  
|<   111   112   113   114   115   116   117   118   119   120   121   122   123   124   125   126   127   128   129   130   131   132   133   134   135  
136   137   138   139   140   141   142   143   144   145   146   147   148   149   150   151   152   153   154   155   156   157   158   159   160   >>   >|  
should pass through (D) or (G) after a few seconds. When assured that the fittings are tight, close (h) and open (a) cautiously to admit air to restore atmospheric pressure. This precaution is essential, as a sudden inrush of air will project liquid from (D) or (F'). Reconnect the rubber tube with the flask (A). Open the pinchcocks (a) and (k) and blow over about 10 cc. of the hydrochloric acid from (A) into (B). When the action of the acid slackens, blow over (slowly) another 10 cc. The rate of gas evolution should not exceed for more than a few seconds that at which about two bubbles per second pass through (G) (Note 2). Repeat the addition of acid in small portions until the action upon the limestone seems to be at an end, taking care to close (a) after each addition of acid (Note 3). Disconnect (A) and connect the rubber tubing with the soda-lime tube (K) and open (a). Then close (k) and open (h), regulating the flow of water from (H) in such a way that about two bubbles per second pass through (G). Place a small flame under (B) and !slowly! raise the contents to boiling and boil for three minutes. Then remove the burner from under (B) and continue to draw air through the apparatus for 20-30 minutes, or until (H) is emptied (Note 4). Remove the absorption apparatus, closing the stopcocks on (F) or stoppering the open ends of (F'), leave the apparatus in the balance case for at least thirty minutes, wipe it carefully and weigh, after opening the stopcocks (or removing plugs). The increase in weight is due to absorption of CO_{2}, from which its percentage in the sample may be calculated. After cleaning (B) and refilling (H), the apparatus is ready for the duplicate analysis. [Note 1: The absorption tubes or bulbs have large surfaces on which moisture may collect. By allowing them to remain in the balance case for some time before weighing, the amount of moisture absorbed on the surface is as nearly constant as practicable during two weighings, and a uniform temperature is also assured. The stopcocks of the U-tube should be opened, or the plugs used to close the openings of the Geissler bulb should be removed before weighing in order that the air contents shall always be at atmospheric pressure.] [Note 2: If the gas passes too rapidly into the absorption apparatus, some carbon dioxide may be carried through, not being completely retained by the absorbents.] [Note 3: The essential ionic changes involved in t
PREV.   NEXT  
|<   111   112   113   114   115   116   117   118   119   120   121   122   123   124   125   126   127   128   129   130   131   132   133   134   135  
136   137   138   139   140   141   142   143   144   145   146   147   148   149   150   151   152   153   154   155   156   157   158   159   160   >>   >|  



Top keywords:

apparatus

 
absorption
 

minutes

 

stopcocks

 

weighing

 

moisture

 
contents
 
balance
 

slowly

 

addition


bubbles

 

rubber

 

essential

 

assured

 

action

 
seconds
 

pressure

 
atmospheric
 

absorbents

 

analysis


duplicate

 

collect

 

surfaces

 
sample
 

weight

 

removing

 

increase

 

percentage

 
involved
 

cleaning


refilling

 

calculated

 
passes
 

rapidly

 

carbon

 

opened

 
removed
 
Geissler
 

openings

 

opening


temperature
 

uniform

 

carried

 

completely

 

remain

 

allowing

 

amount

 
absorbed
 

dioxide

 
weighings