use.] [Note 2: Soda-lime absorption tubes are to be preferred if a satisfactory quality of soda lime is available and the number of determinations to be made successively is small. The potash bulbs will usually permit of a larger number of successive determinations without refilling, but they require greater care in handling and in the analytical procedure.] [Note 3: Soda lime is a mixture of sodium and calcium hydroxides. Both combine with carbon dioxide to form carbonates, with the evolution of water. Considerable heat is generated by the reaction, and the temperature of the tube during absorption serves as a rough index of the progress of the reaction through the mass of soda lime. It is essential that soda lime of good quality for analytical purposes should be used. The tube should not contain dust, as this is likely to be swept away.] [Note 4: The solution of the hydroxide for use in the Geissler bulb must be highly concentrated to insure complete absorption of the carbon dioxide and also to reduce the vapor pressure of the solution, thus lessening the danger of loss of water with the air which passes through the bulbs. The small quantity of moisture which is then carried out of the bulbs is held by the calcium chloride in the prolong tube. The best form of absorption bulb is that to which the prolong tube is attached by a ground glass joint. After the potassium hydroxide is approximately half consumed in the first bulb of the absorption apparatus, potassium bicarbonate is formed, and as it is much less soluble than the carbonate, it often precipitates. Its formation is a warning that the absorbing power of the hydroxide is much diminished.] !The Analysis! PROCEDURE.-- Weigh out into the flask (B) about 1 gram of limestone. Cover it with 15 cc. of water. Weigh the absorption apparatus (F) or (F') accurately after allowing it to stand for 30 minutes in the balance case, and wiping it carefully with a lintless cloth, taking care to handle it as little as possible after wiping (Note 1). Connect the absorption apparatus with (e) and (f). If a soda-lime tube is used, be sure that the arm containing the soda lime is next the tube (E) and that the glass stopcocks are open. To be sure that the whole apparatus is airtight, disconnect the rubber tube from the flask (A), making sure that the tubes (a) and (b) do not contain any hydrochloric acid, close the pinchcocks (a) and (k) and open (h). No bubbles
PREV.   NEXT  
|<   110   111   112   113   114   115   116   117   118   119   120   121   122   123   124   125   126   127   128   129   130   131   132   133   134  
135   136   137   138   139   140   141   142   143   144   145   146   147   148   149   150   151   152   153   154   155   156   157   158   159   >>   >|  



Top keywords:
absorption
 

apparatus

 

hydroxide

 
reaction
 

quality

 

wiping

 

determinations

 

number

 

carbon

 

dioxide


solution

 
calcium
 

prolong

 
potassium
 
analytical
 

soluble

 

formation

 

bubbles

 

warning

 

bicarbonate


absorbing

 

formed

 

precipitates

 

diminished

 

Analysis

 
carbonate
 

limestone

 

accurately

 

PROCEDURE

 

airtight


stopcocks

 

disconnect

 
rubber
 

hydrochloric

 

making

 

carefully

 

lintless

 

balance

 

minutes

 

Connect


pinchcocks
 
taking
 

handle

 

allowing

 

pressure

 
combine
 

carbonates

 
hydroxides
 
sodium
 

procedure