FREE BOOKS

Author's List




PREV.   NEXT  
|<   2   3   4   5   6   7   8   9   10   11   12   13   14   15   >>  
eed this to determine reason for damage. Normally claims for any and all damages should be filed with the freight company within five working days after receipt of shipment. All materials are sold F.O.B. Factory. It is the responsibility of the consignee to file claim with the delivering carrier for material received in a damaged condition. _LOCATING UNIT_ _BEFORE REMOVING SHIPPING CARTON, LOCATE UNIT IN ITS FINAL POSITION_ The carton is plainly marked so as to indicate which is the outlet burner end of the unit which is also the end where the return and flue are located. Clearance should be provided in both the front and rear of the unit for cleaning. Where possible it is good practice to locate the unit so its sides are parallel to the chimney flue. In all instances locate unit as near chimney flue as possible in order to avoid use of a long flue pipe. _REMOVING CARTON_ Once the packaged unit is in its proper place, cut all around the carton on the scored line as shown on carton. The entire carton may then be lifted from the skids. If it is found necessary to move the unit a little more to place it in the exact location ready for piping, do so before removing skids. DO NOT PUSH AGAINST ANY PART OF JACKET OR OIL BURNER WHEN MOVING UNIT. TO MOVE UNIT, PUSH AGAINST _SKIDS, FLUE BOX OR SMOKE BOX_. PUSHING AGAINST JACKET WILL RESULT IN DAMAGE. _REMOVING SKIDS_ The skids are specially designed for easy removal. It is necessary, however, to follow these instructions carefully. A. After unit is in proper place, remove the two cross pieces from skids by pulling out all scaffolding (double headed) nails. B. By inserting pinch bar or 2" x 4" underneath the smoke box (rear of unit), tilt one side of unit just high enough to lift lugs out of holes in skid, then knock skid out from underneath unit. Then do the same thing on the other side of unit. _THE UNIT IS NOT BOLTED TO THE SKIDS._ The 3/4" lugs welded to the unit simply fit into the 3/4" holes in the skids. +----------------------------------------------+ | | | IMPORTANT | | | | DO NOT TILT UNIT BY PUSHING AGAINST JACKET | | | | IT IS NOT NECESSARY | |
PREV.   NEXT  
|<   2   3   4   5   6   7   8   9   10   11   12   13   14   15   >>  



Top keywords:
AGAINST
 

carton

 

JACKET

 

REMOVING

 

chimney

 

underneath

 
proper
 
PUSHING
 
CARTON
 

locate


specially

 

removal

 

DAMAGE

 
designed
 

RESULT

 

NECESSARY

 

removing

 

MOVING

 

BURNER

 

pieces


simply

 

BOLTED

 

welded

 

inserting

 
remove
 

instructions

 

carefully

 

IMPORTANT

 
double
 

headed


piping

 

pulling

 
scaffolding
 

follow

 
delivering
 

carrier

 

consignee

 

responsibility

 
Factory
 

material


received
 
LOCATE
 

POSITION

 

SHIPPING

 

BEFORE

 

damaged

 
condition
 

LOCATING

 

materials

 

Normally