The Project Gutenberg EBook of Installation and Operation Instructions For
Custom Mark III CP Series Oil Fired Unit, by Anonymous
This eBook is for the use of anyone anywhere at no cost and with
almost no restrictions whatsoever. You may copy it, give it away or
re-use it under the terms of the Project Gutenberg License included
with this eBook or online at www.gutenberg.org
Title: Installation and Operation Instructions For Custom Mark III CP Series Oil Fired Unit
Author: Anonymous
Release Date: February 25, 2009 [EBook #28166]
Language: English
Character set encoding: ASCII
*** START OF THIS PROJECT GUTENBERG EBOOK OIL FIRED UNIT ***
Produced by Gerard Arthus, Diane Monico, and the Online
Distributed Proofreading Team at http://www.pgdp.net
INSTALLATION
AND
Operation Instructions
FOR
CUSTOM MARK III
CP SERIES OIL FIRED UNIT
MANUFACTURED BY
AXEMAN-ANDERSON COMPANY
300 East Mountain Avenue
South Williamsport, PA 17701
CPO2O--8410--5C
INSTALLATION AND OPERATING INSTRUCTIONS
CUSTOM MARK III
CP SERIES OIL FIRED UNIT
_GENERAL_
The Custom Mark III CP Series Oil Fired Unit is a high quality heating
unit that will provide many years of comfortable and economical heat if
properly installed and given proper care. It is _IMPORTANT_ therefore that
these instructions should be followed carefully.
_SHIPMENT_
The unit is completely assembled at the factory except for the following
parts which are packed in a separate carton and strapped to the skids
inside the shipping carton:
1 - 3/4" x Close Steel Nipple
1 - 3/4" x 3/4" x 1/2" Tee
1 - Fig. 105 Tridicator
1 - 3/4" No. 10-402-05 ASME Relief Valve
1 - 3/4" No. 600-19 Boiler Drain
1 - T87F-2055 Thermostat
The jacket extension for 128CPO is shipped in separate carton.
_DAMAGE IN TRANSIT_
Upon receipt of shipment of this material, inspect all cartons for
external damage. If external damage is noted, open the carton and
inspect for damage to equipment. Mark the number of cartons received in
this condition on the delivering carrier's waybill, and request the
services of their inspector.
If, upon opening a carton, concealed damage is discovered, open the
entire shipment and note all equipment so damaged. Contact the
delivering carrier and request inspection of the damaged equipment. Do
not destroy the carton. The inspector from the freight company will n
|