when the dynamos were connected direct. In the former case the increase of volts was proportional to the length of main used, and 8,500 at Deptford gave 10,000 at London. Mr. Blakesley described a simple method of determining the loss of power in a condenser by the use of three electrodynamometers, one of which has its coils separate. Of these coils, one is put in the condenser circuit, and the other in series with a non-inductive resistance r, shutting the condenser. If a_{2} be the reading of a dynamometer in the shunt circuit, and a_{3} that of the divided dynamometer, the power lost is given by r (Ca_{3} - Ba_{2}) where B and C are the constants of the instruments on which a_{2} and a_{3} are the respective readings. Prof. S.P. Thompson asked if Mr. Swinburne had found any dielectric which had no absorption. So far as he was aware, pure quartz crystal was the only substance. Prof. Forbes said Dr. Hopkinson had found a glass which showed none. Sir William Thomson, referring to the same subject, said that many years ago he made some tests on glass bottles, which showed no appreciable absorption. Sulphuric acid was used for the coatings, and he found them to be completely discharged by an instantaneous contact of two balls. The duration of contact would, according to some remarkable mathematical work done by Hertz in 1882, be about 0.0004 second, and even this short time sufficed to discharge them completely. On the other hand, Leyden jars with tinfoil coatings showed considerable absorption, and this he thought due to want of close contact between the foil and the glass. To test this he suggested that mercury coatings be tried. Mr. Kapp considered the loss of power in condensers due to two causes: first, that due to the charge soaking in; and second, to imperfect elasticity of the dielectric. Speaking of the extraordinary rise of pressure on the Deptford mains, he said he had observed similar effects with other cables. In his experiments the sparking distance of a 14,000 volt transformer was increased from 3/16 of an inch to 1 inch by connecting the cables to its terminals. No difference was detected between the sparking distances at the two ends of the cable, nor was any rise of pressure observed when the cables were joined direct on the dynamo. In his opinion the rise was due to some kind of resonance, and would be a maximum for some particular frequency. Mr. Mordey mentioned a peculiar phenomenon observed i
PREV.   NEXT  
|<   38   39   40   41   42   43   44   45   46   47   48   49   50   51   52   53   54   55   56   57   58   59   60   61   62  
63   64   65   66   67   68   69   70   71   72   73   74   75   76   77   78   79   80   81   82   83   84   85   86   87   >>   >|  



Top keywords:

observed

 

condenser

 

cables

 

showed

 

absorption

 

coatings

 
contact
 

sparking

 

circuit

 
pressure

dielectric

 

dynamometer

 

completely

 

Deptford

 
direct
 

mercury

 
suggested
 

remarkable

 

mathematical

 

considerable


Leyden
 

discharge

 

sufficed

 

tinfoil

 

thought

 
effects
 

joined

 

dynamo

 

distances

 

terminals


difference

 

detected

 

opinion

 

mentioned

 

peculiar

 
phenomenon
 

Mordey

 
frequency
 

resonance

 

maximum


connecting

 
soaking
 

imperfect

 

elasticity

 

Speaking

 

charge

 
considered
 

condensers

 
extraordinary
 
transformer