FREE BOOKS

Author's List




PREV.   NEXT  
|<   304   305   306   307   308   309   310   311   312   313   314   315   316   317   318   319   320   321   322   323   324   325   326   327   328  
329   330   331   332   333   334   335   336   337   338   339   340   341   342   343   344   345   346   347   348   349   350   351   352   353   >>   >|  
.................................................. 7 Duration............................................................hours 8 Kind and size of coal.................................................... AVERAGE PRESSURES, TEMPERATURES, ETC. 9 Steam pressure by gauge............................................pounds 10 Temperature of feed water entering boiler.........................degrees 11 Temperature of escaping gases leaving boiler......................degrees 12 Force of draft between damper and boiler...........................inches 13 Percentage of moisture in steam, or number degrees of superheating..................per cent or degrees TOTAL QUANTITIES 14 Weight of coal as fired[72]........................................pounds 15 Percentage of moisture in coal...................................per cent 16 Total weight of dry coal consumed..................................pounds 17 Total ash and refuse...............................................pounds 18 Percentage of ash and refuse in dry coal.........................per cent 19 Total weight of water fed to the boiler[73]........................pounds 20 Total water evaporated, corrected for moisture in steam............pounds 21 Total equivalent evaporation from and at 212 degrees...............pounds HOURLY QUANTITIES AND RATES 22 Dry coal consumed per hour.........................................pounds 23 Dry coal per square feet of grate surface per hour.................pounds 24 Water evaporated per hour corrected for quality of steam...........pounds 25 Equivalent evaporation per hour from and at 212 degrees............pounds 26 Equivalent evaporation per hour from and at 212 degrees per square foot of water-heating surface........................pounds CAPACITY 27 Evaporation per hour from and at 212 degrees (same as Line 25).....pounds 28 Boiler horse power developed (Item 27/34-1/2)...........boiler horse power 29 Rated capacity, in evaporation from and at 212 degrees per hour....pounds 30 Rated boiler horse power...............................boiler horse power 31 Percentage of rated capacity developed...........................per cent ECONOMY RESULTS 32 Water fed per pound of coal fired (Item 19/Item 14)................pounds 33 Water evaporated per pound of dry coal (Item 20/Item 16)...........pounds 34 Equivalent evaporation from and at 212 degrees per pound of dry coal (Item 21/Item 16)...............
PREV.   NEXT  
|<   304   305   306   307   308   309   310   311   312   313   314   315   316   317   318   319   320   321   322   323   324   325   326   327   328  
329   330   331   332   333   334   335   336   337   338   339   340   341   342   343   344   345   346   347   348   349   350   351   352   353   >>   >|  



Top keywords:

pounds

 

degrees

 
boiler
 

evaporation

 

Percentage

 
evaporated
 
Equivalent
 
moisture

weight

 

consumed

 
capacity
 

QUANTITIES

 

refuse

 
square
 
corrected
 
surface

Temperature
 

developed

 

Evaporation

 
CAPACITY
 

ECONOMY

 

RESULTS

 

Boiler

 

quality


heating

 
pressure
 

escaping

 

entering

 

Duration

 

TEMPERATURES

 

PRESSURES

 

AVERAGE


leaving
 

Weight

 

equivalent

 

superheating

 

damper

 
number
 

inches

 

HOURLY