r. 106. Q. Explain the passage of steam from the boiler to the steam heat pipe. A. Steam is admitted to the steam heat pipe, in which there is placed a reducing valve through which it passes at reduced pressure, into the steam heat pipe under the entire length of the train. The reducing valve is located in the cab close to the steam heat throttle. 107. Q. If the steam heat gauge shows proper pressure, but the steam heat pipe pressure appears to be low, what should be done? A. If the steam heat gauge is showing the correct pressure, there is an obstruction in the pipe somewhere, most likely in the steam heat hose, and this should be looked for and remedied; if the gauge is correct, then it is the reducing valve that is at fault and this should be readjusted, as well as the gauge. 108. Q. What is the cause of failure with the second injector, and what should be done to obviate this failure? A. Lack of attention and failure to use every day will allow joints to work loose and boiler check to fill up with mud and scale. It should be tested every day and worked regularly so as to keep it in good working order. 109. Q. If an injector stops working while on the road, what should you do? A. Would first ascertain if sufficient water was in the tender and tender valve open, and that water was cool enough in the tender so the injector would handle it. Would next see that no obstruction was in the feed pipe or strainer and that the feed pipe was free from leaks, and that the injector was getting a sufficient supply of steam. If the injector would not prime, would see whether overflow or heater valve could open wide, or if overflow pipe was obstructed. If suction pipe was very hot would blow water back into tank and let suction fill with cold water. If possible, examine for obstruction in the steam priming tube and water tubes. If it would prime and fail to deliver water to the boiler, would see that the delivery tube was not obstructed and then look for trouble at the boiler check. An obstruction in the tubes would stop the injector working at once, while wear of the tubes or filling up with scale would affect the injector gradually. 110. Q. What are the advantages of the combination boiler check and stop valve? A. A combination boiler check is fitted with a valve similar to a globe valve and can be closed at will. Its advantage is that the boiler pressure can be shut off from the check and the valve repaired
PREV.   NEXT  
|<   54   55   56   57   58   59   60   61   62   63   64   65   66   67   68   69   70   71   72   73   74   75   76   77   78  
79   80   81   82   83   84   85   86   87   88   89   90   91   92   93   94   95   96   97   98   99   100   101   102   103   >>   >|  



Top keywords:
boiler
 

injector

 

pressure

 
obstruction
 

failure

 

tender

 
working
 

reducing

 

sufficient

 
obstructed

overflow

 

suction

 

combination

 
correct
 
strainer
 

fitted

 

advantages

 

repaired

 
supply
 

similar


closed

 

advantage

 

handle

 

deliver

 

delivery

 

priming

 

heater

 

filling

 

affect

 

examine


gradually

 

trouble

 
proper
 

throttle

 

appears

 
showing
 

located

 

admitted

 

passage

 

Explain


length

 

entire

 
passes
 

reduced

 

looked

 
remedied
 

regularly

 
worked
 
tested
 
readjusted